Column Definition File (.sch)
The .sch database schema file contains the data types of database table columns.
Description
The data type of program variables or form fields used to hold data of a given database column must match the data type used in the database. The definition of these elements is simplified by centralizing the information in external .sch files, which contain column data types.
The .sch file can be produced by the fgldbsch tool, from the system views of the target database.
In form files, you can directly specify the table and column name in the field definition in the
ATTRIBUTES
section
of forms.
In programs, you can define variables with the data type of a database column by using the LIKE
keyword.
As column data types are extracted from the database system tables, you may get different results
with different database servers. For example, Informix®
provides the DATE
data type to store simple dates in year, month, and day format (=
DATE
FGL type), while Oracle® stores dates as year to second ( = DATETIME YEAR TO SECOND
FGL
type).
The table describes the fields you will find in a row of the .sch file:
Pos | Type | Description |
---|---|---|
1 | STRING |
Database table name. |
2 | STRING |
Column name. |
3 | SMALLINT |
Coded column data type. If the column is NOT
NULL , you must add 256 to the value. |
4 | SMALLINT |
Coded data type length. |
5 | SMALLINT |
Ordinal position of the column in the table. |
This table shows the data types and their corresponding type code that can be present in a schema file:
Data type name | Data type code (field #3) | Data type length (field #4) |
---|---|---|
CHAR |
0 | Maximum number of characters or bytes (see note) |
SMALLINT |
1 | Fixed length of 2 |
INTEGER |
2 | Fixed length of 4 |
FLOAT / DOUBLE
PRECISION |
3 | Fixed length of 8 |
SMALLFLOAT / REAL |
4 | Fixed length of 4 |
DECIMAL |
5 | If the decimal is defined with a precision and scale, the length is computed using this formula:
If the decimal is defined as a floating point decimal (i.e. with no scale), the length is computed as follows:
|
SERIAL |
6 | Fixed length of 4 |
DATE |
7 | Fixed length of 4 |
MONEY |
8 | The length is computed using this formula:
A |
Unused | 9 | N/A |
DATETIME |
10 |
For
where digits is the total number of digits used when displaying the datetime
value. For example, a The qual1 and qual2 elements identify datetime qualifiers using the following codes:
For example, a DATETIME YEAR TO MINUTE size length is computed as follows:
|
BYTE |
11 | Length of descriptor |
TEXT |
12 | Length of descriptor |
VARCHAR |
13 | Maximum number of characters or bytes (see note) If the length is positive:
If length is negative:
|
INTERVAL |
14 |
For
where digits is the total number of digits
used when displaying the interval value. For example, a The qual1 and qual2 elements identify datetime qualifiers according to this list:
For example, an
|
NCHAR |
15 | Maximum number of characters or bytes (see note) |
NVARCHAR |
16 | Maximum number of characters or bytes (see note) |
INT8 |
17 | Fixed length of 10 (size of int8 structure) In programs, will
be converted to a |
SERIAL8 |
18 | Fixed length of 10 (size of int8 structure) In programs, will
be converted to |
BOOLEAN (SQLBOOL ) |
45 | Boolean type, in the meaning of Informix front-end SQLBOOL
(sqltype.h) |
BIGINT |
52 | Fixed length of 8 (bytes) |
BIGSERIAL |
53 | Fixed length of 8 (bytes) |
VARCHAR2 |
201 | Maximum number of characters In programs, will be converted to
a |
NVARCHAR2 |
202 | Maximum number of characters In programs, will be converted to
a |
SMALLINT
value encoding the
length or composite length of the type. For character string types, the unit of the length used to
define character program variables and form fields depends on the length semantics.Informix SERIAL types
When the database schema defines SERIAL
, BIGSERIAL
or
SERIAL8
types, form fields referencing the serial column will get the NOENTRY
attribute automatically,
except if defined with the TYPE LIKE
syntax.
Informix CHAR/VARCHAR types and SQL_LOGICAL_CHARS
The Informix SQL_LOCICAL_CHARS onconfig parameter is
taken into account when extracting CHAR/VARCHAR
column types, to convert the size
in bytes from syscolumns.collength to a number of characters for the .sch
file.
Informix DISTINCT types
Informix IDS version 9.x and higher allow you to
define DISTINCT
types from a base type with the CREATE DISTINCT
TYPE
instruction. In the syscolumns table, Informix identifies distinct types in the coltype column by adding the 0x0800 bit (2048) to
the base type code. For example, a distinct type defined with the VARCHAR
built-in type (code 13) will be identified with the code 2061 (13 + 2048). Informix sets additional bits when the distinct type is based on the
LVARCHAR
or BOOLEAN
opaque types. If the base type is an
LVARCHAR
, the type code used in coltype gets the 0x2000 bit set (8192) and when the
base type is BOOLEAN
, the type code gets the 0x4000 bit (16384).
When extracting a schema from an Informix database
defining columns with DISTINCT
types, the schema extractor will keep the original
type code of the distinct type in the .sch file for columns using distinct
types based on built-in types (with the 0x0800 bit set). Regarding the exception of opaque
types, BOOLEAN
-based distinct types get the code 45 ( + 256 if NOT
NULL
), and LVARCHAR
-based distinct types are mapped to the code 201 (+ 256
if NOT NULL
) if the -cv
option enables conversion from
LVARCHAR
to VARCHAR2
.
The fglcomp and fglform compilers understand the distinct
type code bit 0x0800, so you can define program variables with a DEFINE LIKE
instruction based on a column that was created with a distinct Informix type.
Example
customer^customer_num^258^4^1^
customer^customer_name^256^50^2^
customer^customer_address^0^100^3^
order^order_num^258^4^1^
order^order_custnum^258^4^2^
order^order_date^263^4^3^
order^order_total^261^1538^4^